Switch User Manual
54
C H A P T E R 3 Standard Configuration
54
Adaptive Forwarding Mode
Purpose You can:
• Change the Sample Time
• Define the minimum and maximum errors acceptable before 
changing the forwarding mode
Note While CRC errors and runts are the most likely parameters 
to cause the switching mode to change, they are not the only 
ones.
Changing the time to 
measure errors
The sample time should be the shortest time needed to detect errors. 
If the sample time is too great, there may be too many errors before 
the forwarding mode changes. To change the time the switch retains 
error counters:
1 Select Device Setup or Stack Setup.
2 Click Switching.
3 Click Advanced.
4 Click Sample Time.
5 Type the required number of seconds.
6 Click OK.
Changing number of 
errors before adaptive 
forwarding mode operates
Adaptive forwarding changes the forwarding mode depending on the 
upper and lower limits of specific error types. To change the number 
of upper and lower limits:
1 Select Device Setup or Stack Setup.
2 Click Switching.
3 Click Advanced.
500.book Page 54 Thursday, September 2, 1999 1:17 PM