User's Manual
Table Of Contents
- Ref. V10-122006
- Features
- Mullion Mounting
- Indications
- Connections
- Output protocols
- Security
- Specifications
- Timing
- Installation instruction
- Mullion Mounting
- Connector Assignments
- Tamper Switch
- Mounting tool
- Mounting Plate (Spacer)
- _
- _
- _
- © Copyright 2007
- Issue: May 2007 – This manual supercedes and rend
- The information in this manual has been put toget
- The installation recommendations contained in this manual assume the most favorable framework conditions. The manufacturer cannot guarantee that the system will function perfectly under other conditions.
- The manufacturer cannot guarantee that the information contained in this document is not protected by external property rights. The manufacturer is not granting licenses to its own or external patents or other property right.
- _
- _
- _
Connector Assignments
input
Do not
connect
Wiegand RS232 RS422
Clock/Data
(ABA)
RS485
Do not
Connect
1
Green LED
input
Green
LED input
Green
LED
input)**
Do not
Connect
RXD
RXB
Green
LED
input)**
Green
LED
input)**
2
Red LED
input
Red LED
input
Red LED
input)**
Red LED
input)**
Red LED
input)**
3
Data
D1
Do not
connect
TXA
D0
TXD
TXB
TRX
5
Buzzer
input
16.00
VDC
Power
4.5 to
TRX
16.00
VDC
4
Attention: 4.5 Volt DC is MINIMUM VOLTAGE AT
READER CONNECTOR PINS
Clock
Buzzer RXA Do not
Connect
Do not
Connect 6
Ground Ground Ground Ground Ground
7
8 Power Power Power Power
4.5 to 4.5 to 4.5 to 4.5 to
16.00 VDC 16.00
VDC
16.00
VDC
Optional tamper contact: rating 1A 30 VDC
** LED input only valid in read-only applications