User's Manual
11
Short product specifications and part numbers/article codes
Typical read range with an ISO Card
ISO14443-3 up to 5 cm (1.97 inches)
ISO14443-4 uo to 5 cm (1.97 inches)
Read range depends on card type and communication speed.
Power Supply
8 – 24 Volt DC
Power consumption
Average 2.5 Watt
Peak 5 Watt
Interface
Inputs EMC Prot. 10Kohm pull-ups
Outputs EMC Prot. open drain 0.5 A/max
Dimensions
243 x 95 x 66 mm (9.57 x 3.74 x 2.60 inches)
Material housing
aluminium
Operating temperature
-20° to 60° C (32° to 140° F)
Humidity
Up to 100% non-condensing
Note:
The SmarTOUCH Xtreme is also designed for outdoor use.
Nevertheless special precautions are recommended for to allow for a
convenient user experience. Snow, a cold or wet finger sensor will not
invite to use the reader. For outdoor use we recommend to mount the
reader under a cover.
Cable Distance
Up to 150 meter (492 foot); depending on output protocol and cable type.
Recommended cable type: stranded conductor with overall stranded shield or
equivalent
SIA recommended cable type for Wiegand signals
Cable Length Cable Diameter inch Diameter mm
Up to 61m (200.1 ft) AWG22 0.025 0.64
Up to 91m (301.8 ft) AWG20 0.03 0.82
Up to 153m (502 ft) AWG18 0.04 1.02
Recommended cable for clock and data ABA track 2 emulation: Up to 25 meter