Proximity Card Reader SmartID Ref.
This manual is applicable for the following SmartID products: • • • • • • • • • 800-8002 800-8003 800-8001 800-8015 800-8016 800-8008 800-8025 800-8030 800-8045 • • • • • • 800-8062 800-8077 800-8060 800-8061 800-8076 800-8075 • 800-8063 • 800-8078 • 800-8080 • 800-8085 • 800-8081 • 800-8086 • 800-8100 • 800-8110 SmartID/EM4102 SmartID/EM4102/RS232/RO SmartID/EM4102/pin SmartID/Hitag1&2 SmartID/Hitag1&2/RW SmartID/Hitag1&2/PIN Mifare Serial number Reader/Rs232 ISO14443-3 Mifare Sector reader ISO14443-3
Table of content: Features............................................................. 4 Mullion Mounting ............................................... 5 Indications......................................................... 5 Connections ....................................................... 5 Output protocols ................................................ 5 Security.............................................................. 6 Specifications.....................................................
Features The Smart ID Reader has a slim door style mountable design to match any decor. The sunk LED’s and buzzer allow the Smart ID Readers to be mounted indoors and outdoors. The Smart ID Reader accepts 5 to 12 Volts DC. The reader output formats like clock-and-data magstripe (ABA / ISO7811), Wiegand and a number of other formats are determined by the personalization of the card or configuration of the reader.
* Mullion Mounting The Smart ID Readers can be mounted on a door mullion. Optional there is a mounting kit available in case the small Smart ID reader will be mounted over a wall box (mounting US back box, vertical 84 milimeter (3.31 inch), mounting European back box, horizontal 60 millimeter (2.36 inch)). Indications When a proximity card is decoded successfully the with the card associated code is send to the Host system and the buzzer sounds a short 3KHz beep.
Security Depending on the model and the RF technology used the Smart ID Reader Family offers high security challenge response schemes to protect the RFID air interface against various attacks schemes like record & playback attacks.
Specifications Typical read range with an ISO Card EM4102 up to 7.5 cm (2.95 inch) Hitag1&2 up to 8 cm (3.15 inch) ISO14443 up to 3 cm (1.8 inch) ISO15693 up to 15 cm (5.91 inch) DESFire up to 2 cm (0.79 inch) Power Supply 5 – 12 Volt DC Power requirements ISO 14443 readers (UL listed) Average Power Consumption 1.5 Watt Peak Power Consumption 2.0 Watt 125 kHz readers Average Power Consumption 860 mW Peak Power Consumption 940 mW Interface Inputs EMC Prot. 10K ohm pull-ups Outputs EMC Prot. open drain 0.
Certifications CE, FCC, IC FCC ID's are: • EM4102: Smart-ID/EM4102 P4E-SMARTPIN-2 • Hitag1&2: Smart ID/Hitag1&2 P4E-SMARTPIN-2 • ISO14443: Smart ID/ ISO14443/SNR/RS232 P4E-SMARTPIN-1 • ISO 14443-3: Smart ID/ISO14443-3/Sect P4E-SMARTPIN-1 • DESFire: Smart ID/DESFire P4E-SMARTPIN-1 • ISO 14443 & 125 kHz Prox: SmartTRANS P4E-SMARTPIN-4 IC (Canada) • ISO14443: Smart ID/ ISO14443/SNR/RS232 IC: 6690A-SMARTPIN-1 • ISO 14443-3: Smart ID/ISO14443-3/Sect IC: 6690A-SMARTPIN-1 • DESFire: Smart ID/DESFire IC: 6690A-SMAR
UL Listing (listed 800-80XX) The SmartID ISO14443-4DESFire PINpad reader (Wiegand output) is confirm UL294 (Access Control System Units) requirements.
SIA recommended cable type for Wiegand signals Cable Length Cable Up to 61m (200.1 ft) Up to 91m (301.8 ft) Up to 153m (502 ft) AWG22 AWG20 AWG18 Diameter inch 0.025 0.03 0.04 Diameter mm 0.64 0.82 1.02 Recommended cable for clock and data ABA track 2 emulation: Up to 25 meter (82 foot), AWG22.
Timing 11
Installation instruction 1) Determine an appropriate position for the Reader and drill two holes for mounting the reader to the surface (see mullion mounting drawing on 13). Do not mount the readers less than 20 cm (7.87 inch) from each other. Make sure that enough room to connect the cable is allowed. Protect the cable against sharp edges and any damage from chaffing. 2) Remove the Terminal Connector 8 pins from the back of the Reader.
4) After wiring the reader and the Host system the Reader is ready to be tested. Apply power and present a Card to the Reader. The green LED should flash and the buzzer should beep indicating a read. If the Host system is connected to the red and green LED inputs these should follow the functionality of the Host system. 5) The Reader can now be secured to the surface using the appropriate screws. Mount the black cover (sticker) and mount the cap over the mounting hole.
Mullion Mounting The size in the drawing is in mm. 1 mm is 0.039 inch.
Connector Assignments Clock/Data (ABA) Green LED 1 input Wiegand Green LED input RS232* RS422* Green LED Green LED input)** input)** Led LED input Led LED input Led LED input)** Led LED input)** Data D1 Do not connect TXA Clock D0 TXD TXB 5 Buzzer input Buzzer input Do not connect RXA 6 Do not Connect Do not Connect RXD RXB Ground Ground Ground Ground Power 5 to 12.00 VDC Power 5 to 12.00 VDC 2 3 4 7 8 Power Power 5 to 5 to 12.00 VDC 12.00 VDC Attention: 4.
Optional Tamper Switch 16
Optional Mounting tool The sizes in the drawing is in mm. 1 mm is 0.039 inch.
Optional Mounting Plate (Spacer) The sizes in the drawing is in mm. 1 mm is 0.039 inch.
The crossed-out wheeled bin means that within the European Union the product must be taken to separate collection at the product end-of life. This applies to your device but also to any enhancements marked with this symbol. Do not dispose of these products as unsorted. Approval If used according to the instructions, this radio system meets the basic requirements of article 3 and the remaining applicable conditions of the R&TTE directive (1999/5/E6) of March 1999.