Installation Guide
THE FORCE
/
2
Troubleshooting Cont.
TROUBLESHOOTING
B
lower does not Loose wire in electrical Have the system inspected
operate or variable system. and repaired by a
speed does operate. qualified service center.
Worn brushes in blower motor
Have the brushes inspected
and replaced by a
qualified service center.
Inline fuse blown. Turn machine upside
down. Locate fuse holder
on electr
ical box. Remove
blo
wn fuse and replace
with 15 amp AG style fuse.
Agitator trips circuit Low voltage 99-104v. FORCE/2 requires a
breaker at main minimum of 20 amps
panel. @ 115V. Relocate power
cord to a dedicated 20
amp circuit.
Incorrect size extension cord. For an additional 50' run,
use 10/3 cord. For a 100'
run use 8/3 cord.
Pushing down on material Do not push down on
in hopper. insulation while filling hopper.
Wet insulation material in Do not use wet
hopper. material. Disconnect
electrical power and
remove wet material.
W
orn or frozen airlock Have bearing checked and
bearing. replaced by a qualified
t
echnician.
Blower trips circuit Low voltage. Blower requires a minimum
br
eaker at power of 20 amps @ 115V. Use a
source. dedicated refrigerator outlet
or equivalent.
Incorrect extension cord. For an additional 50'
run, use 10/3 cord. For
a 100' run use 8/3 cord.
Operator in attic Static electricity from Mix half-and-half solution
keeps getting insulation. of water and fabric softener.
shocked. Mist into insulation while
loading hopper
.
Note:
Excess moisture will cause
jamming.
Problem Likely Cause Remedy
28