Troubleshooting Cont.
TROUBLESHOOTING
Problem Likely Cause Remedy
27
Machine does not run Main panel circuit Wait for a few minutes,
Cont. breaker tripped. push to reset.
Air, but no material, Slide gate closed. Open to operating
comes out of hose position.
Bridging (air pocket Turn machine “off” and
in hopper). disconnect from electrical
power. Redistribute material
in hopper. Reconnect to
electrical power.
Remote rocker switch for Replace with original
agitator motor has failed. factory part.
Circuit breaker tripped Push to reset.
on main panel.
Jam between blade of Disconnect electrical power.
agitator and airlock. Remove insulation material
from hopper. Locate jam and
remove material with pliers.
Blower power cord is not Check connection on power
plugged in at main panel cord at main panel or
or power cord does not make sure electricity is
have electrical power at present at power
source. source.
S
tart up capacitor blown Have capacitor replaced by
on agitator motor. a qualified service center.
Blower does not Variable speed bypass Position the variable speed
oper
ate or variable switch is in the neutral bypass toggle switch to either
speed does operate. position. the “on” or “o position. If
the switch is located in
between the on/off text, it is
in t
he neutr
al position and t
he
blo
w
er will no
t oper
ate.
Blower rocker switch on Switch rocker to “on”,use
main panel is “off”. remote box to operate.
Remote rocker switch for Replace with original
blower motor has failed. factory part.
Loose power cord/extension
Check condition of
cord at electrical system. electrical plug blades.