4.2.10 LIFE-SPAN(EXPRESS)
The battery shall supply 720 mAh at the 400th cycle under the conditions as follows.
Charge
1C
5
for 72 minutes
Discharge
1C
5
to 1.0V/unit
4.2.11 STORAGE
Within 14 days, the battery shall not cause leakage at 30-60℃ with the relative
humidity at 75%-85%.
4.2.12 VIBRATION
The battery shall not cause damage to its performances when tested with the amplitude
at 4 mm (0.158 inch) and the frequency at 1000Hz.
4.2.13 DROP TEST
The battery shall keep normal when dropped from a height of 450 mm (17.716 inch) to
the wooden board.
4.2.14 SHORT CIRCUIT
The fully charged battery shall not explode when shorted directly by wires.
4.2.15 INCORRECT POLARITY CHARGE
Discharge at 0.2C5 to the end voltage 0V, then discharge by force at 1C5 rate for 60
minutes, and the battery should not explode or break.
5. SUGGESTION & ADVICE
A. The end-voltage is recommended at 1.0±0.1V/unit.
B. The battery may go fail when shorted, over-charged or charged with incorrect polarity.
C. Avoiding soldering directly to the battery.
D. Do not dispose of in fire and keep away from damage.
7. REFERENCE
Please refer to Intec’s Customer Service if there is any question on using batteries.