Datasheet

IMH-1200AA Page 3 of 6
4.2 TEST METHOD AND CELL PERFORMANCES
4.2.1 APPEARANCE
No conspicuous stretches which influence the value of the battery.
4.2.2 CAPACITY
Charge with 0.1C for 14 hours then discharge with 0.2C to the end-voltage 1.0 V/unit,
the capacity shall be more than 1200 mAh.
4.2.3 OPEN-CIRCUIT VOLTAGE
The open-circuit voltage within one hour after full charge shall be more than 1.25V/unit.
4.2.4 INTERNAL IMPEDANCE
Within one hour after full charge, the internal impedance shall be less than 30 mΩ/cell.
4.2.5 HIGH RATE DISCHARGE
The capacity shall be more than 1080 mAh with the constant discharge current of
1200mA to the end voltage of 1.0V after the battery is fully charged.
4.2.6 SELF-DISCHARGE
The capacity shall be more than 720 mAh after the storage of 28 days for the fully
charged battery.
4.2.7 OVER-CHARGE
The battery shall not cause salting, leakage or reformation when charged at 120 mA for
48 hours and the capacity shall be more than 1200 mAh.
4.2.8 OVER DISCHARGE
The battery shall not cause reformation when it is discharged for 24 hours with the
external resistance at 10Ω.
4.2.9 LIFE-SPAN(CUSTOM)
The capacity shall be more than 900 mAh after 500 cycles with the test conditions as
follow:
TEST CONDITION
Cycle-th Charge Rest Discharge
1 Charge at 0.1C
5
f or 14 hours None Discharge at 0.25C
5
for 2.33 h
2 ~ 48 Charge at 0.25C
5
for 3.17 hours None Discharge at 0.25C
5
for 2.33 h
49 Charge at 0.25C
5
for 3.17 hours None Discharge at 0.25C
5
to 1.0V/unit
50 Charge at 0.1C
5
for 14 hours 1 ~ 4 hours Discharge at 0.2C
5
to 1.0V/unit
Intec Industries Co., Ltd.
Room 2703, Well Tech Centre
9 Pat Tat Street, San Po Kong, Hong Kong
Tel : (852) 2885 1100
Fax : (852) 2947 0588