Datasheet

IMH-1200AA Page 2 of 6
1. PREFACE
This specification applies to the Intec Nickel-Metal Hydride Cylindrical batteries or battery packs.
Intec reserves the right to alter the product design or amend this specification without prior notice.
2. RATINGS
Nominal voltage: 1.2
V.
Nominal capacity: 1200
mAh(0.2C
5
).
Standard charge: 120
mA×14h.
Fast charge: 1200
mA×1.2h.
Trickle charge: 4060
mA.
Discharge cut-off voltage: 1.0
V/unit(20).
Max current of constant discharge: 1200
mA(20,unit cell).
Max current of momentary discharge: 3600
mA(20,unit cell).
Operate temperature range. (Max relative humidity: 85%)
Standard charge -20 ~ +30
Trickle charge 10 ~ +45
Fast charge 10 ~ +45
Discharge -20 ~ +50
storage temperature range. (Max relative humidity: 85%)
Within two years -20 ~ +30
Within two months -20 ~ +45
Within one month -20 ~ +55
Within one week -20 ~ +65
3. EXTERNAL DIMENSION/WEIGHT
3.1 Dimensions: Φ14.0×48.5
(mm);
3.2 Gross weight: 28
(g);
4. CELL PERFORMANCE
4.1 TEST REQUIREMENTS
The following conditions are for new batteries (within one month after delivery under the test
method of 4.2.2.)
Environmental Temperature: +15 ~ +25; Relative humidity: 45% ~ 85%.
Intec Industries Co., Ltd.
Room 2703, Well Tech Centre
9 Pat Tat Street, San Po Kong, Hong Kong
Tel : (852) 2885 1100
Fax : (852) 2947 0588