Datasheet
IMH-1200AA Page 2 of 6
1. PREFACE
This specification applies to the Intec Nickel-Metal Hydride Cylindrical batteries or battery packs.
Intec reserves the right to alter the product design or amend this specification without prior notice.
2. RATINGS
★ Nominal voltage: 1.2
V.
★ Nominal capacity: 1200
mAh(0.2C
5
).
★ Standard charge: 120
mA×14h.
★ Fast charge: 1200
mA×1.2h.
★ Trickle charge: 40~60
mA.
★ Discharge cut-off voltage: 1.0
V/unit(20℃).
★ Max current of constant discharge: 1200
mA(20℃,unit cell).
★ Max current of momentary discharge: 3600
mA(20℃,unit cell).
★ Operate temperature range. (Max relative humidity: 85%)
Standard charge -20 ~ +30℃
Trickle charge 10 ~ +45℃
Fast charge 10 ~ +45℃
Discharge -20 ~ +50℃
★ storage temperature range. (Max relative humidity: 85%)
Within two years -20 ~ +30℃
Within two months -20 ~ +45℃
Within one month -20 ~ +55℃
Within one week -20 ~ +65℃
3. EXTERNAL DIMENSION/WEIGHT
3.1 Dimensions: Φ14.0×48.5
(mm);
3.2 Gross weight: 28
(g);
4. CELL PERFORMANCE
4.1 TEST REQUIREMENTS
The following conditions are for new batteries (within one month after delivery under the test
method of 4.2.2.)
Environmental Temperature: +15 ~ +25℃; Relative humidity: 45% ~ 85%.
Intec Industries Co., Ltd.
Room 2703, Well Tech Centre
9 Pat Tat Street, San Po Kong, Hong Kong
Tel : (852) 2885 1100
Fax : (852) 2947 0588