User manual
SGM PilotBox Function Overview
6 Function Overview
The SGM PilotBox provides you with the following functions:
Support of the IEC 61851 standard, charging method Mode 3
- Pilot signal generation and monitoring incl. duty cycle for signalling
the max. charging current
- Proxmity / resistance coding detection of the charging cable
- Load contactor control
- Connector locking control and monitoring
- Ventilation control and monitoring
Additional functions for "Stand-Alone" operation and operation with a
control logic
- Release input
- Output signal "charging cable detected" (PlugIn Detection)
- Output signal for stating the detected cable capacity (resistance
coding)
- Inputs for determining the maximum charging current to be sig-
nalled via the pilot signal
Additional functions for controlling the Mennekes actuator for con-
nector locking
- Internal generation of the supply for the Mennekes actuator (12 V)
when operating with 24 V
- Integrated emergency power supply for opening the connector
locking o the Mennekes actuator in case of a power failure or other
failures
21