Datasheet
Functions and their Configuration INSYS ETHERNET 5.X
44
Nov-06
Note
For most systems, the command „arp“ can only be performed by the
user „root“.
Note
The Windows command line entry interprets entries for numeral
values with a leading '0' as octal numbers.
E.g. ping 192.168.100.015 actually goes to the host .13
Reason: octal '15' = decimal '13'
It is also advisable not to use leading zeros for ping, Arp, Telnet or
similar commands.
7.4.3 IP block formation
The INSYS Ethernet maps a serial interface on an Ethernet port. In simple words: a serial
cable (or a modem connection) is replaced by an Ethernet connection.
However, there is a significant distinction between the two transmission types: While for
the cable (or modem) the data can be transmitted into both directions as permanent
data stream, for an Ethernet connection data packets are transmitted as blocks. The IN-
SYS Ethernet therefore collects the data to be transmitted for a defined period and then
sends them to the remote terminal in one individual packet. As a countermove, the bytes
of a data packet which was received via Ethernet is continuously sent via the serial inter-
face.
RS232
ETH ETH ETH
ETH ETH
ETH
RS232
remote stationapplication
The INSYS Ethernet has several algorithms which determine when the data collection is
finished and the packet is sent.
IP block formation after the block formation time has expired.
IP block formation when the maximal block size is reached
IP block formation when a trigger byte occurs
IP block formation after the block formation time has expired