7.3.5 Leased line operation
In leased line operation, a permanent connection to a defined remote terminal is main-
tained. If this connection is interrupted at any time, the system will automatically at-
tempt to establish a new connection every 20 seconds.
The function just needs to be activated at one of the two devices involved in the leased
line. The other device must be configured for automatic connection acceptance
(ATS0=n).
For the stability of the connection it is also advisable to activate the KeepAlive function
(see Chapter Fehler! Verweisquelle konnte nicht gefunden werden.) on both sides.
Pertinent AT commands
AT&L<n>
Activate the leased line operation
AT&Z0="<ip ad-
dress>":<port>
Definition of the remote terminal
ATS0=<n>
Automatic connection acceptance
AT#KEEP=<n>
Function check of the existing data connection
7.4 More Functions
The functions described in the following paragraph can not be performed with the PC
configuration software HSComm.
7.4.1 Reset / Default / Factory reset
Reset
When a reset is performed (device is switched on, reset key, AT#RBT), the last profile
that was stored using AT&W is loaded.
Reset options:
Device is switched on
Reset key or terminal
AT command: AT#RBT
AT command: ATZ
Default settings
The default settings (defaults) are loaded with the command AT&F.
Use the command sequence AT&F&W to put the device back into default state (&F resets
the current settings and &W stores these settings in the fail-safe memory). All settings
that can be stored with AT&W are affected by AT&F. The network settings will not be af-
fected, because otherwise the INSYS Ethernet could not be reached via Telnet afterwards.