Network settings (see Chapter 4.4.1):
Has the IP address already been allocated to another device? Unplug the net-
work cable, repeat the ping ... is there a response?
If the PC and the INSYS Ethernet are located in the same local network seg-
ment, then the network codes must be identical and the device numbers must
be different.
If the PC and the INSYS Ethernet are located in different networks, which are
connected through a gateway (e.g. router), then the PC as well as the INSYS
Ethernet must have the according local IP address of the gateway registered.
The GW address must be in the same local network segment.
Firewalls and routers may block certain protocols, address ranges, ports, etc.
In case of doubt please consult your responsible network administrator.