Datasheet

INSYS GSM 4.2
INSYS GSM 4.2 compact
Functions and their Configuration
Sep-06 77
Outgoing calls from the INSYS GSM are not affected.
Procedure: Activate security callback
1. Start the HSComm and switch to the tab "Access control".
2. Enter the requested number in the group "Callback number"
Pertinent AT commands
AT**PASS
Password
AT**DIAL
Connection attempts
AT**CALLBACK
Target number security callback