Datasheet

INSYS GSM 4.2 I4 Functions and their configuration
60
Dez-06
Meaning of the entries:
Reason Detail Meaning
RTC ERROR Internal real time clock is faulty (time stamp empty)
RTC RESET The internal real time clock has been reset as the gold cap was dis-
charged (power reserve used up). Time stamp: 00:00:00 01.01.03
GSM ERROR Instruction from controller to GSM engine could not be processed cor-
rectly (e.g. AT command, dial-up, SMS dispatch…)
SIGNAL ERROR
Field strength not ascertainable (
AT**SIGNAL?
: 99)
LOGOUT GSM engine logged out (update interval like STATUS LED)
LOGIN GSM engine logged in (update interval like STATUS LED)
REMOTE PARAM Remote configuration started (*** detected)
ALIVE Alive SMS process starts
RESET Software/hardware reset
SYSTEM
POWER UP Power up; upon return of voltage
DPW ERROR Wrong data password or timeout expired
PPW ERROR Wrong configuration password or timeout expired
TPW ERROR Wrong entry of DTMF PIN or timeout expired
CLIP ERROR Call with invalid phone number (selective call acceptance)
SECURITY
SECURITY CALLBACK
Security callback process starts
Start Alarm at alarm input
End Alarm at alarm input processed
ALARM
Quitt Acknowledging an alarm message
Start Outgoing voice connections
Incoming voice connections for activated DTMF processing
Number for outgoing calls
Number for incoming calls for activated selective call acceptance
VOICE
End Voice connection terminated
Start Data connection outgoing or incoming;
Incoming number only for activated selected call acceptance
DATA
End Data connection terminated
Power up Power up SMS was sent
PARAM SMS for configuration has been received*
QUITT SMS with the text QUITT has been received*
SMS
QUITT SMS for acknowledging an configuration SMS has been sent*
DTMF PARAM DTMF command has been detected
*) automatic SMS processing must be activated.
The following columns of the history list are displayed in addition:
Dir
Direction of the logged events:
IN Incoming calls and SMS messages
OUT Outgoing calls and SMS messages
Number
The involved phone numbers, alarm inputs and number of pulses are recorded when ap-
plicable.