Inspection Camerawith Color LCD Monitor
Version 1.0
Please read this user manual carefully before using this product. Failure to understand operation
procedures may result in injury.
INSPECTION TOOL
SPECIFICATIONS
FCC INFORMATION
OPERATION
Effective Pixels 640 x 480
Video System PAL/NTSC
Horizontal Viewing Angle 48°
Minimum Illumination 0 Lux (LED ON)
Waterproof Capacity IP67 (for lens/tube only)
Dimensions of Tube φ 8mm x 980mm (Including Camera)
Dimensions of Handle 257 x 92 x 44(mm) (Excluding Flexible Tube)
Operating Temperature -10°C~50°C / 14°F~122°F
Operating Humidity 15~85%RH
Approx. Weight 407g (Including Batteries)
Camera+Handle
Model No. Parameter
Screen Size 2.31”TFT LCD
Contrast 300
Brightness 220CD/M² (TYP)
Power Supply AA x 4 batteries (1.5V x 4)
Work Time 6Hour (Max.)
Consumption Current 238mA
Output Signal Impedance 75ohm
Output Signal Level 0.9--1.3Vp-p
Imaging Sensor 1/9-inch CMOS
Switch on Camera
1. Press and hold on the power switch for about 3 seconds to turn on the
camera, the power indicator will illuminate and the LCD will become viewable.
2. When in use, the tube should easily maneuver itself into position. Do not apply
excessive force.
3. The flexible tube can be bent into numerous shapes that may help you explore
areas you otherwise thought were impossible to see.
4. The accessories included with EXPLORER COMPACT can be used to retrieve
small items like dropped rings or screws.
Mirror Image
In real-time monitoring mode, The mirror image can be adjusted by pressing
the button.
LEDs Brightness Control
The 8 levels of LED brightness can be adjusted by pressing the brightness
button in real-time monitoring.
LCD Contrast Control
The 8 levels of LCD contrast can be adjusted by pressing the contrast
button in real-time monitoring.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
1. This device may not cause harmful interference;
2. This device must accept any interference received, including interfer-
ence that may cause undesired operation. Changes or modifications not
expressly approved by the party responsible for compliance could void
the user’s authority to operate the equipment.
Normal Mirror Normal Upside Down Mirror Upside Down
*All specifications are subject to minor change without prior notice.
EU Environmental Protection
Waste electrical products should not be
disposed of with household waste. Please
recycle where facilities exist. Check with
your local authority or retailer for
recycling advice.