MSDS
---------------------------------------------------------------------------
COMPLEMENTARY COATINGS CORP
MATERIAL SAFETY DATA SHEET
RP2719092-01
---------------------------------------------------------------------------
FIRE-FIGHTING PROCEDURES AND EQUIPMENT
Clear fire area of unprotected personnel. Do not enter confined space
without helmet, face shield, bunker coat, gloves, rubber boots, and a
positive pressure NIOSH-approved self-contained breathing apparatus.
Water spray may be used to cool closed containers to prevent pressure
build-up and possible auto-ignition or explosion when exposed to extreme
heat. Water may be ineffective in extinguishing a paint fire. Therefore,
use caution not to spread flames with stream of water. If water is used,
fog nozzles are preferable.
UNUSUAL FIRE AND EXPLOSION HAZARDS
Keep containers tightly closed. Isolate from heat, electrical
equipment, sparks and open flame. Vapors may be heavier than air and
may travel along the ground to distant ignition sources, then flash
back to the vapor source. Keep welding or cutting equipment away from
product. Containers may explode when exposed to extreme heat.
---------------------------------------------------------------------------
SECTION 6 - ACCIDENTAL RELEASE MEASURES
---------------------------------------------------------------------------
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED
Remove all sources of ignition (flame, hot surfaces and sources of
electrical, static or frictional sparks). Avoid breathing vapors.
Ventilate area. For large spills in a confined area, use self-contained
non-sparking tools. Keep out of drains, sewers and waterways.
CLEAN-UP
Contain and remove with inert absorbent and non-sparking tools.
---------------------------------------------------------------------------
SECTION 7 - HANDLING AND STORAGE
---------------------------------------------------------------------------
HANDLING
Keep away from heat, sparks and open flame. Use only with adequate
ventilation. Keep from contact with oxidizing materials. Comply with
all national, state, and local codes pertaining to the storage, handling
dispensing and disposal of flammable liquids.
STORAGE
Do not store above 120 Degrees F. Close container after each use.
SPECIAL COMMENTS
Do not take internally. Wash with soap and water before eating,
drinking, smoking or using toilet.
---------------------------------------------------------------------------
SECTION 8 - EXPOSURE CONTROLS, PERSONAL PROTECTION
---------------------------------------------------------------------------
VENTILATION
Provide general dilution or local exhaust ventilation in volume and