Installation Care and Use Manual
Property Damage: Do not pinch or break copper
tubing. Do not distort the last 1 inch of tubing.
Make sure to use fiber gasket 
to ensure proper seal.
Unpack dispenser components. 
On a firm, flat surface, carefully
straighten the copper tubing using
hands only.
 Ensure that the fiber gasket is
properly seated against the base 
of the dispenser head.
2
B
A
Fiber
Gasket
H770
H770
 From below the sink, place semi-
circular metal mounting plate over 
the mounting screw, ensuring the
mounting plate covers the sink hole.
 Slide washer over so that the screw
is now inside the smaller hole.
Tighten the screw until snug.
 Feed tubes down the hole in the sink
or countertop until the base is at rest
on the sink or countertop surface.
 Position faucet head at the 
desired angle.
Half moon shaped metal mounting plate
should cradle all descending tubes.
An assistant may be needed to hold 
the dispenser head in place 
while securing the dispenser.
C
D
H770
H770
DO NOT remove mounting screw or
fiber gasket from base of dispenser.
9