Use and Care Manual
Table Of Contents
Turn off water supply before starting.
Installation must comply with all state and local laws and regulations.
Property Damage: Do not extend the lines farther
than the 16" provided. Ensure tube(s) and “Y”
connnector are securely fit.
Personal Injury: Do not locate filter above an
outlet or other electrical device. Install head and bracket
so that connections require no stretching, kinking or
pinching of tubing.
It is normal for approximately 2 oz. of water
to discharge when filter is removed.
Property Damage: Tube runs need to form to the
cabinet’s contours to allow storage space with no sharp
bends. Tubes need clean, perpendicular,
burr-free cuts to ensure a true fit.
a
c
From water
supply line
To dispenser
d
INSTALLING FILTRATION SYSTEM
b
From water
supply line
To dispenser
Scalding Hazard: The faucet dispenses near-boiling
(212ºF) water which can instantly cause scalds or burns.
Use care when operating this appliance.
Property Damage: Join remaining tube
to cold water supply only.
Turn on the water supply.
Depress the dispenser’s HOT handle
and hold it until water flows from the
spout (approximately 1 to 2 minutes).
Flush 3 gallons (11.4 L) through filter
before first use (approximately 4
minutes).
Check all connections to ensure they
are tight and that there are no leaks.
Install a T-fitting (not included)
onto the cold water supply line.
Install dedicated water control valve
with 1/4" compression fitting.
At the end of the white 1/4" tube
from the filter or quick-connector,
slide the supplied brass nut and
ferrule over the tube and then push
in the brass tube insert.
Insert the white 1/4" tube into the 1/4"
compression fitting and tighten.
FINAL WATER CONNECTION
TURN ON WATER & CONNECT POWER
Brass Nut
Ferrule
Brass
Insert
1/4"
Plastic
Tube
3
2
1
5
4
a
a
From filter or
water supply line
Plug
From filter or
water supply line
HC1100, HC2200,
HC2215
C1100, GN1100, GN2200,
GN2215, HC3300, H3300
Determine length of tubing required,
then cut to length making sure the cut
is perpendicular and burr-free.
Insert a white 1/4" tube into inlet side
of filter head until it stops. Press in
again to ensure a secure fit.
Insert the other white 1/4" tube into
outlet side of filter head until it stops.
Press in again to ensure a secure fit.
Separate cartridge from filter head.
Mark hole locations for filter head
and bracket in a spot that allows
for filter replacement.
Drill 1/8" starter holes and attach bracket
to wall with wood screws, turning until snug.
Insert cartridge into filter head. Top
surface of cartridge will become flush with
bottom of filter head when fully engaged.
Connect remaining white 1/4" tube to
incoming water supply line.
Insert the copper tubes(s) from the
dispenser into “Y” quick-connector
using the plug for hot-only models.
Connect the white 1/4" tube from
the right outlet on the filter head into
the quick-connect fitting until it stops.
Press in again to ensure a secure fit.
To remove tube(s) or plug from quick-connector,
depress the release ring and gently pull away.
Screws provided are for use in wood
studs or cabinets only. Use wall anchors
(not supplied) for installation into drywall.
NOTICE
NOTICE
NOTICE
Refer to the Performance Data Sheet for InSinkErator Filter System Models
F-1000S or F2000S. Contact an authorized InSinkErator service agent for repairs
or replacement components. Replacement lters F-1000 and F-2000 can be
ordered by calling 800-558-5700, visiting shop.insinkerator.com, or by contacting
an authorized InSinkErator reseller.
The F-1000S is tested and certied by NSF International against NSF/ANSI
Standard 42 in the following InSinkErator Systems Only: GN1100, HC1100,
GN2200, HC2200, GN2215, HC2215, H3300 or HC3300 for the reduction
of the claims specied on the Performance Data Sheet.
The F-2000S is tested and certied by NSF International against NSF/ANSI
Standards 42 and 53 in the following InSinkErator Systems Only: GN1100,
HC1100, GN2200, HC2200, GN2215, HC2215, H3300 or HC3300 for the
reduction of the claims specied on the Performance Data Sheet.
Pressure: 30-80 psi (207-550 kPA)
Temperature: 33˚F - 100˚F
Flow Rate: 0.75 gpm
Capacity: 500 gallons