User Manual
Table Of Contents
- IMPORTANT SAFETY PRECAUTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- FOR YOUR SAFETY
- Additional safety instructions
- SAVE THESE INSTRUCTIONS
- Features
- Installing
- Operating instructions
- Before you begin using your range
- Using the surface burners
- Using the oven
- Minimum and maximum settings
- Positioning the oven racks
- Using the oven vent
- Using the oven light
- Tips for baking
- Setting the clock
- Selecting the 12-hour or 24-hour display setting
- Using the timer
- Baking
- Adjusting the thermostat
- Convection baking and roasting
- Air Frying
- Programming the cook time
- Programming a delayed start time
- Broiling
- Keeping food warm
- Switching between Fahrenheit or Celsius
- Turning sound on or off
- Locking oven controls
- Maintenance
- Cleaning and maintenance
- Cleaning the control panel
- Cleaning painted parts and decorative trim
- Cleaning stainless steel surfaces
- Cleaning the oven racks
- Cleaning the oven door
- Cleaning the surface element control knobs
- Cleaning the cooktop
- Removing and replacing the oven door
- Removing and replacing the storage drawer
- Self-cleaning the oven
- Steam cleaning the oven
- Troubleshooting
- Specifications
- ONE-YEAR LIMITED WARRANTY
- Cleaning and maintenance
www.insigniaproducts.com
19
4.8 Cu. Ft. Electric Convection Range with Self Clean and Air Fry
7 CAUTION: Check the voltage after connecting the power cord.
8 Go to Replace the terminal block cover
on page 20.
Connect a 3-wire power cord
1 Remove the three lower terminal screws from the terminal block.
2 Insert the three terminal screws through each power cord terminal ring and into the lower terminals of the terminal
block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block.
3 Tighten screws securely to the terminal block. DO NOT remove the ground strap connection.
4 CAUTION: Check the voltage after connecting the power cord.
5 Go to Replace the terminal block cover
on page 20.
Live 1 - Neutral 120V
Live 2 - Neutral 120V
Live 1 - Live 2 208V / 240V
Live 1 - Neutral 120V
Live 2 - Neutral 120V
Live 1 - Live 2 208V / 240V
Neutral
Live 2
Live 1
Terminal block
Ground
strap
Live 2
Live 1
Red
Black
White
Neutral
RedBlack White