User Manual
Table Of Contents
- IMPORTANT SAFETY PRECAUTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- FOR YOUR SAFETY
- Additional safety instructions
- SAVE THESE INSTRUCTIONS
- Features
- Installing
- Operating instructions
- Before you begin using your range
- Using the surface burners
- Using the oven
- Minimum and maximum settings
- Positioning the oven racks
- Using the oven vent
- Using the oven light
- Tips for baking
- Setting the clock
- Selecting the 12-hour or 24-hour display setting
- Using the timer
- Baking
- Adjusting the thermostat
- Convection baking and roasting
- Air Frying
- Programming the cook time
- Programming a delayed start time
- Broiling
- Keeping food warm
- Switching between Fahrenheit or Celsius
- Turning sound on or off
- Locking oven controls
- Maintenance
- Cleaning and maintenance
- Cleaning the control panel
- Cleaning painted parts and decorative trim
- Cleaning stainless steel surfaces
- Cleaning the oven racks
- Cleaning the oven door
- Cleaning the surface element control knobs
- Cleaning the cooktop
- Removing and replacing the oven door
- Removing and replacing the storage drawer
- Self-cleaning the oven
- Steam cleaning the oven
- Troubleshooting
- Specifications
- ONE-YEAR LIMITED WARRANTY
- Cleaning and maintenance
www.insigniaproducts.com
18
3 For the conduit installation, insert the conduit strain relief in the 1 1/8 in. (2.8 cm) conduit hole, then install the conduit
through the body of the strain relief and fasten the strain relief with its ring.
If you are connecting a 4-wire power cord, go to Connect a 4-wire power cord
on page 18.
If you are connecting a 3-wire power cord, go to Connect a 3-wire power cord
on page 19.
Connect a 4-wire power cord
1 Disconnect power to the circuit breaker or fuse box before making the electrical connection.
2 Remove the three lower terminal screws from the terminal block and remove the ground screw.
3 Remove and discard the ground strap located between the middle terminal screw and the ground screw. Do not
discard any screws.
4 Insert the ground screw into the power cord ground wire terminal ring and into the frame of the range.
5 Insert the three terminal screws (removed earlier) through each power cord terminal ring and into the lower terminals
of the terminal block. Be certain that the center wire (white/neutral) is connected to the center position of the terminal
block.
6 Reinstall and tighten screws securely to the terminal block.
Conduit hole
Ring
Body
Power cord hole
Neutral
Live 2
Live 1
Terminal block
Neutral
Live 2
Live 1
Red
Black
White
Red
Black
White
Green
Remove
ground
strap
Ground wire