User Manual

26
Understanding protection
functions
Over-temperature protection
To avoid overheating and damage to the flash head,
do not fire more than 30 continuous flashes in fast
succession at 1/1 full power. After 30 continuous
flashes, let your flash cool for at least 10 minutes.
If you fire more than 30 continuous flashes, then fire
more flashes in short intervals, the internal
over-temperature protection function may be
activated and make the recycling time over
10 seconds. If this occurs, let your flash cool about
10 minutes.
When the over-temperature protection is started, is
displayed on the LCD.
The number of flashes that will activate the overheating
protection based on the power output level are:
Power output Number of flashes
1/1 30
1/2 +0.7 40
1/2 +0.3 50
1/2 60
1/4 (+0.3,+0.7) 100
1/8 (+0.3,+0.7) 200
1/16 (+0.3,+0.7) 300
1/32 (+0.3,+0.7) 500
1/64 (+0.3,+0.7)
1000
1/128 (+0.3,+0.7)