Specifications

January 13, 2021
Page 18/31
Document Ref: isp_lora_DS4520_R7
Insight SiP
Green Side 400 avenue Roumanille BP 309 06906 Sophia-Antipolis Cedex France
www.insightsip.com
4.2. SMT Assembly Guidelines
For PCB Land Patterns and Solder Mask layout, Insight SiP recommends the use of the same
dimensions as the module pads, i.e. 0.65 x 0.30 mm for standard pads, 0.70 x 0.70 mm for corner pads,
2.75 x 2.15 mm for mechanical pads.
Please contact Insight SiP for more detailed information.
4.3. Antenna Keep-Out Zone
For optimal antenna performance, it is recommended to respect a metal exclusion zone to the edge of
the board: no metal, no traces and no components on any application PCB layer except mechanical LGA
pads.