Data Sheet
Preliminary Data Sheet
April 23, 2020
Page 6/25
Document Ref: isp_ble_DS1907_R4.docx
Insight SiP
– Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France –
www.insightsip.com
BLE MODULE
ISP1907
2.4. Power Consumption
Parameter
Typ / LL variant
Typ / HT variant
Unit
Radio current, Receiver active
(1)
6.1
6
mA
Radio current, Transmitter active -40 dBm Output Power
(1)
3.4
3.5
mA
Peak current, Transmitter active 0 dBm Output Power
(1)
5.8
6.1
mA
System OFF, no RAM retention, wake on reset
0.3
0.4
µA
System ON, full RAM retention, wake on any event
0.8
1.7
µA
(1) DCDC enable, Power supply 3V, 1 Mbps
2.5. Clock Sources
Parameter
Max
Unit
Internal High Frequency Clock for RF Stability:
32 MHz Crystal Frequency Tolerance
(1)
+/- 40
ppm
Internal Low Frequency Clock for BLE Synchronization:
32.768 kHz Crystal Frequency Tolerance
(1)
+/- 40
ppm
Internal Low Frequency Clock for BLE Synchronization:
RC Oscillator
(2)
+/- 500
ppm
RF Frequency tolerance:
For BLE operation Channels0 to 39
+/- 40
ppm
(1) including initial tolerance, drift, aging, and frequency pulling
(2) Frequency tolerance after calibration
2.6. Radio Specifications
Parameter
Min
Typ
Max
Unit
Operating Frequencies
MHz
RF Channel spacing
1
MHz
Data Rate
125
2000
kbps
RF Output Power, LL variant
-20
+4
dBm
RF Output Power, HT variant
-20
+8
dBm
Rx sensitivity Level 1 Mbps BLE mode, ideal Tx
-94
dBm
Rx sensitivity Level 125 kbps Long Range mode, ideal Tx
-104
dBm
Antenna Gain
dBi
Range Open field, BLE mode @1m height
100
m
Range Open field, Long Range mode +4 dBm @1m height
400
m
2402 2480
1
Specification subject to change without notice.