Installation and Operation Manual
3.30.22 357-00057-02 Rev A © Inovonics, 2022 - www.inovonics.com
EN2222S-60 Fall Detect Pendant
Installation and Operation Manual
1 Overview
The EN2222S-60N fall detect pendant sends an automatic alarm message
when sensors indicate that a resident may have fallen, even if the resident
is unable to press the alarm button.
Note: For UL 2560 installations, refer to the EN6080 Area Control Gateway
Installation Instructions or the EN6040-T Network Coordinator with
Transformer Installation Instructions.
1.1 Inovonics Contact Information
If you have any problems with this procedure, contact Inovonics technical
services:
• E-mail: support@inovonics.com.
• Phone: 1.800.782.2709, option 2.
1.2 Maximum Number of Repeaters for a UL 2560
Installation
To achieve the 99.99% alarm message reliability required for UL 2560
compliance, system installations must operate within the following limits for
end device and repeater counts.
1.3 Pendant Components
Figure 1 Pendant components
2 Installation and Startup
2.1 Installation Notes
• These products are designed to be maintained by professional
technicians.
• Products are intended for indoor use.
• Do not ship the pendant with the coin cell battery installed when
temperatures are below 32°F. Doing so will damage the internal
battery and cause the pendant to irretrievably fail.
• All products should be manually tested weekly (see section 6, “Test
the Transmitter”).
2.2 Coin Cell Battery Installation
Caution: If you are installing batteries in multiple devices, keep the
batteries from coming into contact with each other to prevent discharge.
1. Place the battery in the battery compartment, ensuring that the positive
terminal (+) faces up.
2. Seat the battery door over the battery so that the arrow on the battery
door is lined up with the unlocked padlock icon.
Figure 2 Battery door in the unlocked position
3. Use the ACC680 alarm clearance card or a quarter to turn the battery
door to line up the arrow on the battery door with the arrow under the
locked padlock icon.
Figure 3 Battery door in the locked position
4. Press the activation button for at least one second.
• The red LED will flash and the pendant will vibrate, indicating that an
alarm has been sent. (For more information, see section 3.1, “Send a
Resident-Initiated Alarm” on page 2.)
5. Clear the alarm sent when you activated the pendant per section 3.3,
“Clear an Alarm”.
2.3 Register the Transmitter
The transmitter sends a check-in message to the receiver or gateway every
60 minutes for the purposes of supervision. The transmitter must be
registered and supervised.
Caution: The EN2222S-60 fall detect pendant must have a supervision
window of no more than 12 hours to avoid not discovering a missing device
within 24 hours.
Each transmitter has a unique factory-programmed identification number.
Refer to the receiver or gateway's installation instructions for details on
registering and setting up supervision.
1. When prompted by the receiver or gateway to reset transmitter, press
the activation button, and then clear the alarm per section 3.3, “Clear an
Alarm”.
Caution: The transmitter should be tested after registration to ensure
operation. See section 6, “Test the Transmitter”.
For product and installation videos visit us at
www.inovonics.com/videos or use the QR
code below.
End Devices Maximum
Repeaters
150 397
250 386
350 375
500 360
1000 313
2000 238
3000 184
A Activation button B Transmit and alarm clear
LED
C Low battery LED
D Vented battery
door
E Attachment loop
B
C
A
D
E
Unlocked
position
Locked
position