-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this unit not expressly approved by Innovative Wireless
Technologies, Inc. may void the user’s authority to operate this equipment.
Innovative Wireless Technologies, Inc.
1047 Vista Park Drive, Suite A
Forest, VA 24551
1-434-316-5230 (United States)
www.iwtwireless.com (United States)
2.2 DEVICES INSTALLED IN UNDERGROUND COAL MINES (FMN ONLY):
This device has been evaluated by the Mine Safety and Health Administration (MSHA) per Title
30 Code of Federal Regulations Part 23.
MSHA Intrinsic Safety Evaluation Number: 23-ISA080005-0
Per MSHA’s evaluation, this product has been determined to be intrinsically safe under the
following conditions:
• The FMN is installed ONLY in areas where permissible equipment is not required.
• The FMN is installed with the following intrinsically safe backup battery assembly:
Innovative Wireless Technologies FAP9100-002
• The FMN is installed with the following 900 MHz antenna:
M-2 Antenna Systems, Inc. Model No. 902-5 or 902-5MA
The antenna must be located a minimum 7.1 feet from any blasting circuits.
• When installed, power cables (AC or DC) must not be intermingled with RF coax cables
used to connect the antenna to the FMN.
• When installed underground in coal mines, the FMN must be installed as part of a MSHA
approved system. The FMN must be installed per installation instructions described in
Section 5.0 as well as per any instructions / documentation applicable to the specific
MSHA approved system.