4. Technical Data
Applicable Standards
Canadian Standards Association (CSA)
CAN/CSA-C22.2 No. 92 Standard for Dehumidifiers
Underwriters Laboratories
®
(UL)
UL 474 Standard for Dehumidifiers
Approvals, Certifications
Energy Star
®
IW25-3 is an Energy Star certified dehumidifier
Intertek ETL
Complies with CAN/CSA-C22.2 No. 92; cETL Listed
Complies with UL-474; ETL Listed
People's Choice Award, AIA
Top New Innovative Product, 2014 AIA National Convention
Physical Properties
See Table 1.
5. Installation
Preparatory Work
Deliver product in manufacturer's original, unopened, undamaged
containers with identification labels intact. Store protected
from exposure to harmful environmental conditions, frost-free
and at temperature and humidity levels recommended by the
manufacturer.
I
W25-3 requires a drain and 120V power. Ensure provisions are
made for power and for draining condensate from the unit and
confirm that obstructions, such as plumbing or electric lines, do
not block unit placement. Where sound is a concern, mount the
unit at the back of the room.
Do not remove any co
mponents of the IW25-3 dehumidifier,
including the Styrofoam noise insulation shroud.
Precautions
I
f hard-wired, IW25-3 should be installed and inspected by
a qualified e lectrician a nd i n a ccordance w ith a ll a pplicable
electrical and plumbing codes. Be certain power is turned off
and unplugged or the circuit breaker is off before and during
installation and maintenance. Ensure the unit is connected to a
wiring system with an equipment-grounding conductor.
For stairwells and hallways, ensure the installed unit provides
sufficient clearance for pedestrian traffic.
Methods
In-wall Installation
Locate wall studs at the desired location for installation. Cut a
rough opening 14.5" wide by 25.5" high, ensuring a minimum
Table 1 – Technical Properties
Rated average power consumption
(at 80° F, 60% RH)
285 W
Max power consumption
(at 90° F, 95 RH)
310 W
Max absorbed current
(at 80° F , 60% RH) F.L.A.
2.05 A
Locked rotor current (LRA) 14.0 A
Air flow (with clean air filter) 150 CFM
Second pressure level
(at 3 MTS in free field)
<47 dbA
Refrigerant R134A
240 G
Defrosting control system
Electrical
Drain connection
3/4" hose
Functioning temperature range
50–90° F
Functioning relative humidity range
35–95%
Rated condensation capacity
(at 80° F, 60% RH)
27 ppd
Power supply
120V, 1-phase, 60 Hz AC
Power cord
10', 3-prong GFI
Refrigerant
R134a
Sample Installation