User's Manual
B-6 Appendix Installation Manual
mounted too close to metal or if a metal
object is placed too close to it.
LED4
(Valid Tag Detected; Steady Yellow)
This LED indicates the presence of a Tag in
a zone.
Table B.10
LED4 status Signals
Off No Tag(s) Present
On, steady Yellow Tag(s) Detected
LED5
(Rx Signal Indicator; Steady Green)
This LED indicates the presence of a Tag,
418 mHZ interference in a zone or Band
Removal.
This LED is lit dimly when a Tag is in the
zone. If this LED lights very brightly (and
there are no Tags in the zone) the Receiver
is being interfered with or is misadjusted.
Table B.11
LED5 status Signals
Off No Tag(s) Present
On, dimly,
steady Green
Tag(s) Detected
On, brightly,
steady Green
Zone Receiver problem
LED6
(
Lock Indicator; Steady Yellow)
This LED indicates the status of the Lock(s)
or Elevator Deactivation Relay.
NOTE: Voltage from the Fire Panel
Interface (FPI) must be present for this LED
to function.
Table B.12
LED6 status Signals
Off No Tag(s) present
On,
steady Yellow
Tag(s) present in zone,
Lock or Elevator
Deactivation Relay is
engaged
NOTE: LED6 will remain on (and the Locks
or Elevator Deactivation Relay will remain
engaged) after the Tag leaves the zone for as
long as the delay time has been set.
LED7
(Alarm Indicator; Flashing Red)
This LED indicates an “open door”
condition after a Tag as been detected.
Table B.13
LED7 Status Signals
Off No Tag(s) present
On, flashing Red Tag(s) detected
and an “open
door” condition
NOTES:
This LED will continue to flash red until the
“open door” condition is corrected (close the
door and enter a valid code into the
Keypad). In hallway situations, a triggered
Passive Infrared Reader (PIR) is also an
“open door” condition.
LED8
(Door Ajar Indicator; Steady Red)
This LED indicates a Door Ajar condition.
Table B.14
LED8 Status Signals
Off No Tag(s) Present
On, steady Red Door Ajar condition