Installation Manual UL Addendum (UL 294, BP9480) v
9. The magnetic switch shall be UL Listed as a connector and switches.
10. Wiring of FPI must be wired to fail-safe in an alarm or loss of power condition.
11. The Passive Infrared Detector for use with this system is not intended to be used as an
intrusion detector. It is for monitoring use only.
12. The following components have not been evaluated as a UL Listed access control unit
accessory (although they may carry other UL listings): Local Alarm (LA), Central Alarm
CA3), Speakers (AS3), Timer (DNT), LED Tag (LED), Multi-Tone Local Alarm (MTLA),
Push Button Override (PBO), Tag Test Station (TTS) (the Tx antenna portion of the TTS
has not been tested), Voice Alarm (VA)
13. The detection range for a zone-activated Tag is approximately 8 ft. but the actual range
shall be determined by the Installation Test (Facility Performance Testing).
14. The Tag’s (LT, SB, BR, CB) battery status shall be checked with a TAD, PTAD at least
twice daily.
15. The ESRR (remote receiver) may be used if the desired signal cannot be achieved with
the internal receiver.
16. Models ESI and ESR are provided with a tamper switch.
17. Model ES has only been tested by UL for use in the ESI or ESR system.
18. The Tag Model CB’s Pod (plastic covers) has not been evaluated by UL.
19. The Tag’s (LT, SB, BR, CB) battery is not replaceable in the field.