User's Manual

11-6 Magnetic Locks Installation Manual
The delay time is set by Position 3 on the
Selector Switch (S1) on the Lock PCB (
see
Figure 11.2
).
The OFF position results in a 1-second
delay
The ON position results in a 3-second
delay
Changing the Egress Alarm delay time
The Egress Alarm delay time requires a door
disturbance to be sustained for a set length of
time before unlocking the door and allowing
egress.
The delay time is set by Position 4 on the
Selector Switch (DS1) on the Lock PCB (
see
Figure 11.2
).
The OFF position results in a 15-
second delay
The ON position results in a 30-second
delay
3000 Magnetic Locks
3000 Magnetic Lock Specifications
Mounting the 3000 Magnetic Lock
Connecting the 3000 Magnetic Lock
Changing the Lock Nuisance delay time
3000 Magnetic Lock Specifications
Power Requirements
Temperature
Weight
Power Requirements
12V or 24V AC/DC
Temperature
3000 Magnetic Locks operate best in an ambient
temperature between 35 and 90 degrees
Fahrenheit. Operation outside of this range may
cause unexpected or undesirable results,
including premature failure.
Weight
The 3000 Magnetic Lock weighs 9 U.S. pounds.