User's Manual
Installation Manual Magnetic Locks 11-1
Magnetic Locks
Perimeter Door Applications
Operation of the Magnetic Lock
3101 Series Magnetic Locks
3000 Series Magnetic Locks
Each Magnetic Lock is comprised of 3 basic
components: a lock housing, an electromagnetic
coil and an armature.
The coil and housing assembly mounts rigidly to
the door frame while the armature mounts to the
door in a manner that allows it to pivot slightly
to compensate for door irregularities.
When the door is closed and the lock is
energized the armature is magnetically bonded
to the lock face, thus securing the door without
utilizing any moving parts.
JP9 (External Reset) selects which device will
control the resetting of the Lock after it has been
energized (locked). With the jumper in, a
Keypad reset is required to reset the Lock to its
unlocked state. With the jumper out, the Lock
will return to its unlocked state after the time
delay set on switch S1 expires. In either case, all
Tags must be removed from the monitored zone
for the Lock to be reset.
Perimeter Door Applications
The Lock can be used as an Access Control
device. In normal state, the door will be closed
and locked. Entering a valid code into a Keypad
or activating a PBO will open the door. When
closed again, the door will reset after the
adjustable set period of time.
Operation of the Magnetic Lock
The Magnetic Lock will engage when a Tag is
on the Tx Activation Field. The Lock remains
engaged as long as a Tag is in the Field. JP9
(External Reset) selects which device will
control the resetting of the Lock after it has been
energized (locked). With the jumper in, a
Keypad Reset is required to reset the Lock to its
unlocked state. With the jumper out, the Lock
will return to its unlocked state after the time
delay set on switch S1 expires. In either case, all
Tags must be removed from the monitored zone
for the Lock to be reset.
Once locked, the Lock will disengage when any
of the following conditions occur:
All Tags leave the Field and the switch
S1 time delay expires (JP9 must be
out).
A Keypad Reset (JP9 is in).
A PBO is activated.
The facility’s Fire Alarm is activated.
The removal of power, for any reason,
will de-energize the lock allowing the
door to be opened.
The Central Override is activated
(Optional).
3101 ONLY - When a maintained force
(less than 15 pounds required) is
applied to the door for an adjustable
period of time (1 to 3 seconds).