User's Manual
Installation Manual the Passive Infrared Reader (PIR) 10-3
5. Mount the backplate to the wall using
the screws supplied.
NOTE: For wall and ceiling
installations, use the two knock-outs at
the back of the base. For corner or 45ยบ
mounting use the knock-outs on the
angled sides. The unit must be fastened
securly to the mouting surface to avoid
possibe vibrations.
Connecting the PIR
You will need 22 AWG, 4-conductor cable
(supplied with the door wire kit) for installation.
To connect the PIR to the Controller, refer to
Figure 10-4 (or for PIR in series refer to 10-5)
and use the following instructions:
1. Using the WHITE wire, connect ( C )
of the PIR to P5-pin1 (Out) on the
Controller.
2. Using the GREEN wire, connect (N.C.)
of the PIR to P5-pin2 (In) on the
Controller.
3. Using the BLACK wire, connect (GND)
of the PIR to P8-pin2 (Ground) on the
Controller.
4. Using the RED wire, connect (+12V) of
the PIR to P8-pin3 (+12V) on the
Controller.
Adjusting the PIR beam angle
To change the angle of the PIR beam, use the
following instructions:
1. Loosen the PCB screw and move the
board up or down. The scale on the
lower right side of the board indicates
the angle.
2. Moving the PCB down will increase the
far range and move the near beams
farther out from the mounting wall.
3. Moving the PCB up will reduce the far
range and bring the near beams closer to
the mounting wall.
4. When finished adjusting, tighten the
adjustment screw in place.