LC 1200 Manual The Magnetic Switch 4-3
Wiring
You will need 22-gauge, 2-conductor plenum-
rated cable for this connection.
To wire the Magnetic Switch to the LC unit,
refer to Figure 4.4 and use the following
instructions:
1. Using the RED wire, connect “COM”
on the Switch terminal to P2-4 (Door
Switch In) of the LC unit.
2. Using the BLACK wire, connect
“N.O.” on the Switch terminal to P2-3
(Door Switch Out) of the LC unit.
Figure 4.4
Wiring the Magnetic Switch to the LC unit
Double Doors Applications
For double doors applications, connect the
Switches in series (Figure 4.5) so that one
Switch will open when either door is opened.
Figure 4.5
Wiring Two Magnetic Switches in Series
Perimeter Door Applications
Perimeter Door (No Locks)
Perimeter Door (Locks)
Perimeter Door (No Locks)
The LC unit can be made to function like a
perimeter door and alarm the instant a door is
opened regardless if there is a Tag in the zone.
To activate this mode, remove the jumper (or
terminal block) from P1 pins 1 and 2 (Perimeter
Door) of the LC unit. A Timer can also be used.
When in this mode, whenever the door is opened
(detected by the magnetic door position switch
or PIR tripped), the LC unit will alarm.
To reset the zone, close the door and enter a
valid code into the zone Keypad.
Perimeter Door (Locks)
The LC unit can be used as a perimeter door
access control device. When in this mode, the
door will remain locked (Magnetic Lock
energized) at all times and will require a valid