Owner Manual
10
PERSISTENT MEMORY RESET
Any time you change a DIP switch, other than A1, you must reset persistent memory for your new DIP switch settings changes to
take effect. If you do not reset Persistent Memory, your system may not function properly.
figure 1.11
TO RESET PERSISTENT MEMORY
1. Disconnect power to the spa.
2. Remove and put the jumper across J43, covering both pins.
(see fig. 1.11)
3. Connect power to the spa.
4. Wait until “PR” is displayed on the panel.
5. Disconnect power from the spa, again.
6. Remove jumper from J43 and replace.
7. Reconnect power to the spa.
PRE INSTALLATION
1. The ozone generator or UV sterilizer must be 110V and approved for use on residential spas.
2. A Mazzei 784K, or equivalent, injector is required for the ozone generator installation.
3. The electrical cord must have an amp style, 4 pin, male connector with wire locations as follows:
Balboa ozone connector conguration for 120V 60Hz
Green
Black
Flat sides of sockets as shown
Line - Black conductor
Use this slot for the leftover Red conductor
Common - Install the White conductor here for 120V
ozone
Ground (Green) conductor
OZONE GENERATOR INSTALLATION