The steps are similar to other rates as well.
For TX measurements go to ‘TX’ tab. Before starting TX operations following settings need to
be done on the GUI.
TX Mode: Select ‘Packetized’
Rates: Select the modulation rates want to transmit
o 11b: 1, 2, 5.5 and 11 Mbps
o 11g: 6, 9, 12, 18, 24, 36, 48 and 54 Mbps
o 11n: MCS0 to MCS7
Channel: Select the channel of transmission. Channel 1 (2412M) to channel 13 (2472M)
Data Pattern: Select ‘All 0’
Power: ‘0’ for max power level the device can transmit at. Always use power level “0” for
emission testing in order to verify the max power level settings.
Preamble: Select ‘Long’
Override CCA: Should be unchecked
Size: 100 Bytes (for 11b rates), 1000 Bytes (for 11g rates) and 1000 Bytes (for 11n rates)
Delay: 100msec
Tone: 0
Amount: 0
7. Once the above setting are done, start TX by clicking ‘Start Tx Testing’