4. ELECTRICAL CHARACTERISTICS
4.1 Recommended Operating Range
PARAMETER
CONDITIONS
MIN NOM MAX
UNIT
Operating ambient temperature range, T
A
–40 85
°C
Operating supply voltage
For operation in battery-powered and 3.3V systems
1.9 3.8
V
4.2 Power Consumption
Unless noted, all specifications are at 25 °C and Vbat = 3.0 V.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
Low Power Mode (LPM4.5)
Shutdown. No clocks running, no retention
100
nA
Low Power Mode (LPM3)
With RTC, CPU, RAM and (partial) register retention
1
uA
Power consumption radio RX(2)
With DC/DC
6.1 6.4 6.7
mA
Power consumption radio TX(2)
With DC/DC, 0 dBm output power
6.5 6.8 7.1
mA
Power consumption radio TX(2)
With DC/DC, 5 dBm output power
8.6 8.9 9.2
mA