4: VAM-CM interfaces
Figure 12. Side view dimensions
Figure 13. Rear view dimensions
4.6: Environmental conditions
Environmental operating conditions for VAM-CM are shown in
Table 14
.
Min Nominal Max Unit
Operating temperature -20 +25 +70 Celsius degrees
Humidity 0 90 %
Vibration 0,96
0,96
m
2
/s
2
5 Hz to 20 Hz
m
2
/s
2
20 Hz to 100 Hz
(30 minutes/axis)
(thereafter -3dB/octave)
Table 14. Environmental requirements
21:GSPS Core Module 2.0 VAM-CM HW Description