User Manual

3. Specification
Power
Voltage: 120Vac 60Hz
Current: 15A
Wattage: 1800W
Temperature Probe (optional)
Type of temperature probeR25°C=100KΩ±1%,
R0°C=26.74~27.83KΩ , B25/85°C=3435K±1%
Temperature measurement range-40°C~100°C/-40°F~212°F
Temperature display accuracy0.1°C/°F(<100°C/°F)
1°C/°F(>=100°C/°F)
Temperature measurement accuracy
Range of Temperature
Celsius
Celsius Error
Range of Temperature
Fahrenheit
Fahrenheit Error
-40T<10 ±2 -40T<50 ±3
10T<80 ±1 50T<176 ±2
80T≤100 ±2 176T≤212 ±3
Humidity Probe(optional)
Type of humidity probeHTG3515CH
Relative humidity measurement range5~99%RH
Humidity display accuracy0.1%RH
HUMIDITY
Controller Manual
Equivalent to IHC-200
Humidity Controller Manual
ITC-608T
TEMPERATURE
HUMIDITY
Controller Manual
Equivalent to IHC-230
Temperature & Humidity
Controller Manual
ITC-608T
Humidity
Control Mode
ITC-608T + Humidity Probe
Temperature and Humidity
Control Mode
ITC-608T + Temperature Probe
+Humidity Probe