User Manual
18
3.2 Setting Menu Instruction
Code Symbol Function Setting Range
Default
Settings
Annotation
TS tS
Temperature Setting
Value
-40.0℃~100℃
25.0℃
-40.0
℉
~212
℉
77.0
℉
℉
HD H
Heating Difference
Value
0.3℃~15.0℃ 2.0℃
1.0℉~30.0℉ 3.0℉
℉
CD C
Cooling Difference
Value
0.3℃~15.0℃ 2.0℃
1.0℉~30.0℉
3.0℉
AH AH
Alarm High
Temperature Value
-40.0
℃~
100
℃
100
℃
-40.0
℉
~212
℉
212
℉
℉
3.2.1 When TR=1 or 2, menu code setting is as below.
Code Symbol Function Setting Range
Default
Settings
Annotation
UT U
Time Unit Setting
Value
D
:Day, :Hour, :
Minute
MD Cycle Setting Value 0-999 1
When is 00
,
infinite
loop
AT
A
Auto or Manual Mode
0 or 1
0
0:Manually, 1:Automatic
STT S
Time Stage Setting
Value
1-12 1 More details on 4.6.4
SST SS
Start Stage Settings
Value
1~12 1 More details on 4.6.5
3
.
2.2
When STA is set to 12, menu code setting is as below.
Code
Symbol
Function
Default Settings
Annotation
S01 S01 Stage 1 Temperature Setting Value 25.0℃ or 77.0℉ *
H01
H01
Stage 1 Control Duration Value
10
**
U01 U01
Whether to Alarm after the Completion of
Stage1
n ***
S02 S02 Stage 2 Temperature Setting Value
25.0℃ or 77.0℉
*
H02
H02
Stage 2 Control Duration Value
10
**
U02 U02
Whether to Alarm after the Completion of Stage
2
n ***
S03
S03
Stage 3 Temperature Setting Value
25.0℃ or 77.0℉
*
H03
H03
Stage 3 Control Duration Value
10
**
U03 U03
Whether to Alarm after the Completion of Stage
3
n ***
S04
S04
Stage 4 Temperature Setting Value
25.0℃ or 77.0℉
*
H04
H04
Stage 4 Control Duration Value
10
**
U04 U04
Whether to Alarm after the Completion of Stage
4
n ***
S05
S05
Stage 5 Temperature Setting Value
25.0
℃or
77.0
℉
*
H05
H05
Stage 5 Control Duration Value
10
**
U05 U05
Whether to Alarm after the Completion of Stage
5
n ***
S06 S06 Stage 6 Temperature Setting Value
25.0℃ or 77.0℉
*
H06
H06
Stage 6 Control Duration Value
10
**
U06
U06
Whether to Alarm after the Completion of Stage
n
***
AL AL
Alarm Low
Temperature Value
-40.0℃~100℃ -40.0℃
-40.0℉~212℉ -40.0℉
PT P Compressor Delay
0~10 minutes
0 minute More details on 4.3
CA CA
Temperature
Calibration
-9.9℃~9.9℃ 0.0℃
More details on 4.4
More details on 4.1
More details on 4.2
-15.0
℉
~15.0
℉
0.0
℉
CF CF
Fahrenheit or Celsius
Setting
C or F F More details on 4.5
TR Timer Setting
0、1 or 2
0 More details on 4.6.2
6
S07
S07
Stage 7 Temperature Setting Value
25.0℃ or 77.0℉
*
H07
H07
Stage7 Control Duration Value
10
**
U07 U07
Whether to Alarm after the Completion of Stage
7
n ***
S08
S08
Stage 8 Temperature Setting Value
25.0℃ or 77.0℉
*
H08
H08
Stage 8 Control Duration Value
10
**
U08 U08
Whether to Alarm after the Completion of Stage
8
n ***
S09
S09
Stage 9 Temperature Setting Value
25.0
℃
or 77.0
℉
*
H09
H09
Stage 9 Control Duration Value
10
**
H
H