Use and Care Manual
28
 Output(WORK1/WORK2) Instruction
WORK1: The P1 heating/cooling output
WORK2: The P2 heating/cooling output
 Indicator LED:
●Red LED is on  WORK1 output is on.
●Red LED is blinking WORK1 output is performing the 
function of compressor delay.
●Green LED is on WORK2 output is on.
●Green LED is blinking WORK2 output is performing the 
function of compressor delay.
●Yellow LED is on The controller is in the setting mode.
 Button Instruction
Please read the detail on 2.Button Operation Instructions  below
Probe interface
Two temperature probes can be insert into P1 and P2 interface.
 Temperature probe
●If the controller display Er, you may get a false temperature 
probe, please try harder to insert the probe and rotate it to make 
good contact. If the problem is still persists, it is likely the 
internal probe wire has been damaged by the moisture or heat 
temperature. 
●The probe and cable cannot be touched by the flame. 
●Do not exceed the probe temperature range to avoid 
damaging.
   Functions on screen
PV:In normal mode, the P1 measured temperature is displayed.
 In settings mode, it will display menu code.
P1 Heating indicator LED: If P1 Temperature Control Function 
selected heating mode, the indicator LED is on, otherwise off.
P1 Cooling indicator LED: If P1 Temperature Control Function 
selected cooling mode, the indicator LED is on, otherwise off.
SV:In normal mode, the P2 measured temperature is displayed. 
In setting mode, it will display the setting value.
P2 Heating indicator LED:  If P2 Temperature Control 
Function selected heating mode, the indicator LED is on, 
otherwise off.
P2 Cooling indicator LED: If P2 Temperature Control 
Function selected cooling mode, the indicator LED is on, 
otherwise off.
2 Button Operation Instructions
2.1 Restore Default Settings
Press and hold the “ " button to power on, the buzzer will 
make a short call, indicating that all parameters of the user's 
temperature and humidity probe function return to the default 
setting value.
2.2 “ ” and “ ”Button Function in Normal Operation 
Mode
Press the “ ", PV shows the current temperature setting 
value , SV shows current humidification value; press “ ", PV 
shows current temperature value, SV the current humidification 
setting value , and It will be back to the normal display if there is 
no operation for 3 seconds orpressing the "
SET" button. 
2.3 “SET” Button Function in Normal Operation Mode 
Short press the “
SET” button to enter the quick setting 
temperature and humidity value mode. PV shows the current 
temperature setting value and flashes, and short press “ ” or 
“ ” button to increase or decrease the setting value, long 
press “ ” or “ ”button to quickly increase or decrease the 
setting value, Short press the “
SET” button again,SV shows 
the current humidity setting value and flashes, and short press 
“ ” or “ ” button to increase or decrease the setting value, 
long press “ ” or “ ”button to quickly increase or decrease 
the setting value and lastly press the "
SET" button again to 
confirm and exit. If there is no operation, it will automatically 
exit after 10 seconds and save the setting value.
2.4 Button Function in Setting Mode
When the controller is working normally, press the “SET” button 
for 2 seconds to enter the setting mode,the PV shows the first 
menu code“
 ”, SV shows the corresponding setting value. 
Press “
SET” button to scroll down the menu item and save the 
parameters of the previous menu item. Press“ ” or 
“ ”button to change the current setting value. Selected T to 
enter the temperature parameter modification mode; selected H 
to enter the humidity parameter modification mode. If in the 
setting state, there is no operation within 30 seconds or long 
press "
SET" button for 2 seconds, it will exit and save the 
setting state and return to normal operation mode.
86.8
f
f
P1 Heating 
indicator LED
P1 Cooling 
indicator LED
88.6
f
f
P2 Heating 
indicator LED
P2 Cooling 
indicator LED
A 
96.8
96.8