Use and Care Manual
19
U09  U09 
Whether to Alarm after the Completion of Stage 
9 
n  *** 
S10 
S10 
Stage 10 Temperature Setting Value 
25.0
℃
 or 77.0
℉
* 
H10 
H10 
Stage 10 Control Duration Value 
10 
** 
U10  U10 
Whether to Alarm after the Completion of Stage 
10 
n  *** 
S11 
S11 
Stage 11 Temperature Setting Value 
25.0
℃
 or 77.0
℉
* 
H11 
H11 
Stage 11 Control Duration Value 
10 
** 
U11  U11 
Whether to Alarm after the Completion of Stage 
11 
n  *** 
S12 
S12 
Stage 12 Temperature Setting Value 
25.0
℃
 or 77.0
℉
* 
H12 
H12 
Stage 12 Control Duration Value 
10 
** 
U12  U12 
Whether to Alarm after the Completion of Stage 
12 
n  *** 
* The setting value range is the same as TS
** More details on 4.6.7
*** More details on 4.6.8
4. Control Function Instruction
When the controller works normally, the PV shows the 
measured temperature, meantime the SV screen shows the 
temperature setting value, and automatically recognizes and 
converts for the heating or cooling working mode , in which 
WORK1 is the heating output, furthermore the red led is the 
WORK1 heating output status indicator;WORK2 is cooling 
output, furthermore the green led is WORK2 cooling output 
status indicator.
4.1 Instructions for Setting Temperature Control 
(TS,HD,CD,S01~S12)
4.1.1 TR=0, Temperature Control Mode
4.1.1.1 Normal Temperature Control
When the measured temperature PV ≤ TS(Temperature Setting 
Value) – HD(Heating difference value),the controller will enter 
the heating state, the red led is on, WORK1 output works. 
When the measured temperature PV ≥ TS(Temperature Setting 
Value), the red led is off and the WORK1 output turns off.
When the measured temperature PV ≥ TS(Temperature Setting 
Value) + CD(Cooling difference value), the controller will enter 
the cooling state, the green led is on, WORK2 output works; 
the green led flashes, indicating that the cooling device is in 
the state of the compressor delay protection. When 
PV(measured temperature) ≤ TS(temperature setting value), 
the green led is off and the WORK2 output turns off.