6. Setting Parameters
6.1 Sensor Type and Measuring Range
Sensor Type
Input
Code
Measuring Range
Platinum
Resistor
Pt100
-200~600 (ºC )
-300~1100(ºF )
Cu50
-50~150 (ºC )
-100~300(ºF )
Thermocouple
K
-50~1300 (ºC )
-100~2300(ºF )
S
-50~1700 (ºC )
-100~3000(ºF )
Wre
0~2300 (ºC )
0~4000(ºF )
T
-200~400 (ºC )
-300~750(ºF )
E
0~1000 (ºC )
0~1800(ºF )
J
0~1000 (ºC )
0~1800(ºF )
B
0~1800 (ºC )
0~3200(ºF )
N
0~1000 (ºC )
0~1800(ºF )
Remarks:
The faulty input sensor is the "K" type.
If select the wrong input sensor, the measuring temperature will be incorrect and may
exceed the measuring range with displaying "orAL", control output off.
6.2 Operation Guide
6.21 Boot screen display
6.22 Enter the settings menu
Under measuring and controlling condition, press ▲/▼ to set the temperature value, press