2. Specification
Main features
Fahrenheit and Celsius Display Can Be Choose;
More User-friendly Operating;
Switch Between Cooling and Heating Modes;
Control the Temperature by Setting the Temperature Set Value and the Difference
Value;
Temperature Calibrating;
Refrigerating Control Output Delay Protection;
Alarm When Temperature Exceeds the Limit or When Sensor Error;
Mounting dimension:
Front Panel Size: 75(L)*34.5(W)mm
Mounting Size: 71(L)*29(W)mm
Product Size75(L)*34.5(W)*85(D)mm
Sensor Length: 2m (include the probe)
Temperature Measuring Range
-50210
o
F / -50
o
C-99
o
C
Resolution
0.1
o
F / 0.1
o
C
Measuring Accuracy
±1
o
F-50
o
F -160
o
F/ ±1
o
C-50
o
C -70
o
C
Power Supply
110Vac/220Vac 50Hz/60Hz, 12Vdc
Power Consumption
<3W
Sensor
NTC Sensor
Relay Contact Capacity
Cooling (10A/250VAC)/ Heating (10A/250VAC)
Ambient Temperature
0
o
C - 60
o
C
Storage Temperature
-30
o
C - 75
o
C
Relative Humidity
20-85% (No Condensate)
Warranty
1 Year