Product Manual
Page 10 of 12 66615X-X-C (en)
(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm)).
11-1/2” (292 mm)
19-5/8”
(498 mm)
18-3/8”
(467 mm)
13-1/8” (333 mm)
10-3/4” (273 mm)
12” (305 mm)
2-3/4”
(70 mm)
9” (229 mm)
1/2” Slot (14 mm)
Material Outlet
Figure 6
7-5/8”
(194 mm)
Air Inlet
1/2-14 NPTF-1
Air Exhaust Thread
3/4-14 NPTF-1
14-13/16” (376 mm)
Material Inlet
1-1/2 - 11-1/2 NPTF - 1 (66615X, 66616X)
1-1/2 - 11 BSP (66617X, 66618X)
1-1/2 - 11-1/2 NPTF - 1 (66615X, 66616X)
1-1/2 - 11 BSP (66617X, 66618X)
DIMENSIONAL DATA - 6661X0, 1X2, 1XA and 1XC
Product discharged from exhaust outlet.
y Check for diaphragm rupture.
y Check tightness of (14) diaphragm screw.
Air bubbles in product discharge.
y Check connections of suction plumbing.
y Check “O” rings between intake manifold and uid caps.
y Check tightness of (14) diaphragm screw.
Low output volume, erratic ow, or no ow.
y Check air supply.
y Check for plugged outlet hose.
y Check for kinked (restrictive) outlet material hose.
y Check for kinked (restrictive) or collapsed inlet material
hose.
y Check for pump cavitation - suction pipe should be sized
at least as large as the inlet thread diameter of the pump
for proper ow if high viscosity uids are being pumped.
Suction hose must be a non-collapsing type, capable of
pulling a high vacuum.
y Check all joints on the inlet manifolds and suction con-
nections. These must be air tight.
y Inspect the pump for solid objects lodged in the dia-
phragm chamber or the seat area.
TROUBLE SHOOTING
RELEASED 13/Nov/2018 12:24:00 GMT