INSTALLATION OF ELECTRONIC INTERFACE COMPONENTS FOR HAZARDOUS DUTY
APPLICATIONS
Pumps that will operate in environments dened as “hazardous locations” must only be installed, connected and set-up by
qualied personnel with knowledge and understanding of protection classes, regulations and provisions for apparatus in haz-
ardous areas, for the region where the pump will operate, because these regulations and provisions, along with the denition
of what constitutes hazardous areas vary by location.
Solenoid PN Voltage Device Rating (mA) Temperature Rating
114772-33 120 VAC 57 -4° F - 140° F (-20° C - 60° C)
114772-38 12 VDC 375 -4° F - 140°F (-20° C - 60° C)
114772-39 24 VDC 191 -4° F - 140° F (-20° C - 60° C)
117345-35 (ATEX) 220 VAC 22 -4° F - 140° F (-20° C - 60° C)
117345-38 (ATEX) 12 VDC 392 -4° F - 140° F (-20° C - 60° C)
117345-39 (ATEX) 24 VDC 192 -4° F - 140° F (-20° C -60° C)
End of Stroke Proximity Sensor PN Voltage Device Rating (mA) Temperature Rating
97398 (ATEX/IECEx/NEC/CEC) 7.5 - 30 VDC 50 mA -4° F - 158° F (-20° C - 70° C)
97399 (ATEX/IECEx/NEC/CEC) 7.5 - 30 VDC 50 mA -4° F - 158° F (-20° C - 70° C)
Barrier Amplier, End of Stroke Voltage Device Rating (mA) Temperature Rating
97491 (ATEX/IECEx) 19.2 - 31.2 VDC 12 mA -4° F - 140° F (-20° C - 60° C)
97412 (NEC/CEC) 24 VDC 100 mA -4° F - 140° F (-20° C - 60° C)
Zener Barrier, Leak Detection PN Voltage Device Rating (mA) Temperature Rating
97414 (ATEX/IECEx/NEC/CEC) 24 VDC 100 mA -4° F - 140° F (-20° C - 60° C)
Leak Detector PN Voltage Device Rating (mA) Temperature Rating
96270-1 24 VDC 40 mA -0° F - 176° F (-18° C - 80° C)
96270-2 (ATEX/IECEx) 24 VDC 40 mA -0° F - 176° F (-18° C - 80° C)
Maxmimum process uid and ambient temperatures should not to exceed 50° C.