User's Manual

Access Point Product Specification Product Specification Overview
4 014-0030-00 Rev. G
Requirement Description
Requirement
Comments
Link
Operating Temperature
Range*
-40C +80C
Ambient, not including solar
loading
Operating Temperature Rate
of Change*
-10C +40C
Constant rate of change
measured over 1 hour.
Storage Temperature Range*
-40C +85C
Humidity**
5% 95%
Non-condensing
ESD, EN 61000-4-2
+ 16.5 kV Air Discharge
+ 9 kV Contact Discharge
On any exposed point of an
installed product.
Sine Vibration*
Operating
Non-operating
5 200 Hz, 4 m/s
2
5 200 Hz, 2 m/s
2
Random Vibration*
Operating
Non-operating
5 100 Hz, 1.5 Grms
5 100 Hz, 1.06 Grms
Shock*
Operating
Non-operating
40 G, Half Sine
30 G, Half Sine
Operating Condensation
Cycle**
50 98%
FCC/IC Requirements
15.247, 15.207, 15.215
RSS210e
Single AP FCC ID: XTE-
ULPAP110
IC Emissions Designation:
2M48G1D
4
FCC Requirements
15.247, 15.207, 15.215
Sectorized AP,
FCC ID: XTE-ULPAP210
4
FCC/IC Requirements
15.247, 15.207, 15.215
RSS210e
Dual Latency AP,
FCC ID: XTE-ULPAP310
IC ID: 8655A-ULPAP310
IC Emissions Designation:
2M48G1D
4
ETSI Requirements
300 440-1 and 440-2
301 489-1
IEC/EN/UL/CSA 60950-1
Compliance tests performed.
Documents on file, available upon
request.
4.2
Japan Requirements
Japanese Radio Law; Item 19 of
Article 12
Compliance tests performed.
Category WW, Test Report
R83818.
Access Point Capacity
Typical: 4,000 to 16,000
Maximum: 64,000
The number of nodes an AP can
support is dependent on the
application.
Data Rate
60 kbps
Measured as throughput at each
data point.
Power Source Voltage Range
(PoE)
38 72 VDC
Nominal 48 VDC Power Over
Ethernet.