User's Manual

9 014-0030-00 Rev. G
3 Electrical Characteristics
3.1 Power over Ethernet (PoE)
The nominal 48VDC on the Ethernet cable is separated from the data and regulated with a
switching power supply to 5.0VDC. This printed circuit board is equipped with lightning
protection, surge protection, and differential and common mode filtering. It also includes a
tamper protection device that will report to the system if the box cover has been opened.
NOTE: The AP is not 802.3AF or 802.3AT compliant. It requires a dedicated passive injector
and cannot be powered directly from most PoE switches.
Table 3. Electrical Protection
Surge Life
(@500A
10/1000μs)
Nominal Impulse
Discharge Current
(8/20μs)
Nominal AC
Discharge Current
(10x1sec @50-60Hz)
Max Impulse Discharge
Current
(1 Application @ 10/350μs)
400 shots
10 shots @ 20 kA
20 A
2.5 kA
3.2 Channel Numbering
Channel numbers start at 2402 MHz and are spaced at 1.99 MHz intervals. The following table
lists all channels.
Note the following:
ETSI also uses channels 39 and 40 (1-40). These are not available for the FCC/IC markets.
Japan also has CH41 (2481.60 MHz, 1-41). These are not available for the FCC/IC markets.
ETSI RFID only uses channels 24, 25, 26.
Table 4. Channel Numbers vs. Frequency
1 [L]
2
3
4
5
6
7
8
9
10
2402.00
2403.99
2405.98
2407.97
2409.96
2411.95
2413.94
2415.93
2417.92
2419.91
11
12
13
14
15
16
17
18
19
20 [M]
2421.90
2423.89
2425.88
2427.87
2429.86
2431.85
2433.84
2435.83
2437.82
2439.81
21
22
23
24
25
26
27
28
29
30
2441.80
2443.79
2445.78
2447.77
2449.76
2451.75
2453.74
2455.73
2457.72
2459.71
31
32
33
34
35
36
37
38 [H]
39
40
2461.70
2463.69
2465.68
2467.67
2469.66
2471.65
2473.64
2475.63
2477.62
2479.61