User's Manual
Access Point Product Specification AP Software Configuration via Web Interface
34 010-0021-00 Rev. G
Field
Unit/Forma
t
Description
Power Control Parameters
Target Excess SNR
dB
Default setting is 1 dB. Contact Ingenu
(support@ingenu.com) prior to changing this parameter.
Maximum BCH Power
Control Target
dB
The default value is set according to country-specific
regulatory requirements.
Minimum BCH Power
Control Target
dB
The default value is set according to country-specific
regulatory requirements.
Link Budget
Uplink
dB
This field shows the total amount of link budget available for
the uplink and is not editable.
Downlink
dB
This field shows the total amount of link budget available for
the downlink and is not editable.
AP Maximum EiRP
(Actual)
dBm
The actual maximum EiRP output for the AP.
Node Maximum EiRP
(Actual)
dBm
The actual maximum EiRP output for the Node.
7.4.3 Backhaul Config Submenu
The Backhaul Configuration screen (shown below) displays configuration parameters that were
set at the time the AP was deployed.