User's Manual

Ingal Civil Products
page 8
Release 002
Flexfence
5.9 Installation Checklist
To ensure the correct installation of Flexfence WRSB, you must have answered yes for each question.
End Anchors
Is the anchor block dimensions in accordance with Ingal drawings Yes No
Is the centerline of the anchor block aligned with the centerline of the posts
Yes No
Has the anchor bracket been installed with the leveling plate at the same
longitudinal grade as the roadway
Yes No
Have safety check ropes been attached to each cable
Yes No
Have the safety check ropes been secured to the anchor bracket
Yes No
Has each end fi tting been secured with one washer and two nuts
Yes No
Posts and Fittings – All systems
Have the posts been installed at the correct spacing ensuring suffi cient
clearance to hazards
Yes No
Have the posts been installed with the correct orientation
Yes No
Have ground covers been attached to the posts
Yes No
Have plastic spacers been inserted between each cable
Yes No
Has the stainless frame been inserted between the top and second cable
Yes No
Have post caps been attached to the posts
Yes No
Has delineation been attached to the post caps
Yes No
Posts Fittings – 3 Rope TL4
Has the post reinforcement sleeve been installed at each post location
along the length of need section
Yes No
Have the rope hooks been attached to each post along the length of need section
Yes No
Tension Bays
Have tension bays been installed at not more than 150m from the end anchors Yes No
Have tension bays been installed at not more than 300m apart
Yes No
Has each cable been tensioned in accordance with Table 3
Yes No
Flexfence Pro Man.indd 8Flexfence Pro Man.indd 8 30/11/07 10:46:41 AM30/11/07 10:46:41 AM