Reference Manual

Solid State Relay Control Package Placement
n
Surface Mount in a well ventilated area.
n
Heat Sinks are the 1" deep Aluminum Extrusions
on the left and right sides of the panel. It is
suggested the power be brought in through the top
or bottom of the panel (not from the back).
n
Minimum clearance is 6" on each side, 12" from
the top and bottom. Additional clearance will be
needed if placed in a poorly ventilated area.
n
NEMA 4 Rated, which is completely weather
resistant.
n
Must be accessible per National Electric Code (NEC).
n
NEMA 12 Rated, will need to be mounted in a
well-protected covered area.
n
Zone Analog Controllers can be installed in any
suitable location that will make it convenient to
control the heater(s).
n
Custom NEMA 4 housing also available upon
special order.
14
Control Options
Solid State Relay Placement
Zone Analog Controller Placement